Artwork

内容由Farooq Ahmed提供。所有播客内容(包括剧集、图形和播客描述)均由 Farooq Ahmed 或其播客平台合作伙伴直接上传和提供。如果您认为有人在未经您许可的情况下使用您的受版权保护的作品,您可以按照此处概述的流程进行操作https://zh.player.fm/legal
Player FM -播客应用
使用Player FM应用程序离线!

Buccal Miniscrews: Ramesh Sabhlok

6:14
 
分享
 

Manage episode 361714356 series 2830917
内容由Farooq Ahmed提供。所有播客内容(包括剧集、图形和播客描述)均由 Farooq Ahmed 或其播客平台合作伙伴直接上传和提供。如果您认为有人在未经您许可的情况下使用您的受版权保护的作品,您可以按照此处概述的流程进行操作https://zh.player.fm/legal

Join me for a summary of a lecture by Ramesh Sabhlok, looking at one of the most popular sites for TAD placement, the maxillary buccal interradicular site.

The most common site in maxilla for implant placement is between 2nd premolar and 1st molar in the keratinized gingiva.

Two factors

1. Buccal bone thickness

2. Inter radicular distance

Bone thickness:

· Greatest bone width of bone is between 2nd premolar and 1st molar, and considered ‘safe zone’ thickness of bucco-palatal bone 10.2-11.4mm ( Pogio 2006 Angle orthodontics )

Inter-radicular distance

· 2nd premolar and 1st molar: 3.2mm (SD 0.6mm)- 3.5mm (SD 0.8mm) when 4-6mm from the CEJ, largest clearance of interradicular space in the buccal aspect of maxilla Lee 2009

· Gradually decreases apically, therefore it is advised to place the mini implant at height of 4-6 mm from CEJ, at 2 mm height only 2.7mm interradicular

· In the maxilla, the more anterior and the more apical, the safer the location becomes.

· Increased after levelling and alignment, delay placing if possible

‘SAFE DEPTH’ proposed by Ramesh

· depth of from the bone surface to the narrowest interradicular space at a given height which is safe = 3.2mm interradicular distance for 1.2mm width TAD AND 3.5mm for a 1.5mm TAD.

· Safety depth (height) is 4mm.

o 2mm depth the greatest inter radicular distance 2.4mm, not safe

Angulation

· A 20-30o angle, places the interradicular aspect of the miniscrw apically, where the interradicular is the greatest. This reduces root contact, increases retention with more cortical plate engagement, allows use of longer miniscrews as well as greater distalisation prior to relocation Deguchi 2006.

Extraction of 3rd molars

· Classic papers looking at the Pendulum appliance by Kinzinger 2004 showed extraction of 3rd molars resulted in greater bodily distalisation on the maxillary arch.

· However recent CBCT paper by Lee 2019 show that with miniscrew distalisation there was no difference bodily movement with extraction of 3rd molars and non-extraction.

Concept of biologic width

1-1.5mm of periodontium surrounding the implant,

Lecture title

Summary from AAO 2022 lecture: Non- compliance & Predictable class II correction with Micro implant Anchorage

Dedication

Episode is dedicated to the late Dr Anam Humdani, a London based dentist who tragically died aged 29

https://www.justgiving.com/fundraising/zayaan-humdani

· Contents: Shanya Kapoor

· Editing and Production: Farooq Ahmed

  continue reading

124集单集

Artwork
icon分享
 
Manage episode 361714356 series 2830917
内容由Farooq Ahmed提供。所有播客内容(包括剧集、图形和播客描述)均由 Farooq Ahmed 或其播客平台合作伙伴直接上传和提供。如果您认为有人在未经您许可的情况下使用您的受版权保护的作品,您可以按照此处概述的流程进行操作https://zh.player.fm/legal

Join me for a summary of a lecture by Ramesh Sabhlok, looking at one of the most popular sites for TAD placement, the maxillary buccal interradicular site.

The most common site in maxilla for implant placement is between 2nd premolar and 1st molar in the keratinized gingiva.

Two factors

1. Buccal bone thickness

2. Inter radicular distance

Bone thickness:

· Greatest bone width of bone is between 2nd premolar and 1st molar, and considered ‘safe zone’ thickness of bucco-palatal bone 10.2-11.4mm ( Pogio 2006 Angle orthodontics )

Inter-radicular distance

· 2nd premolar and 1st molar: 3.2mm (SD 0.6mm)- 3.5mm (SD 0.8mm) when 4-6mm from the CEJ, largest clearance of interradicular space in the buccal aspect of maxilla Lee 2009

· Gradually decreases apically, therefore it is advised to place the mini implant at height of 4-6 mm from CEJ, at 2 mm height only 2.7mm interradicular

· In the maxilla, the more anterior and the more apical, the safer the location becomes.

· Increased after levelling and alignment, delay placing if possible

‘SAFE DEPTH’ proposed by Ramesh

· depth of from the bone surface to the narrowest interradicular space at a given height which is safe = 3.2mm interradicular distance for 1.2mm width TAD AND 3.5mm for a 1.5mm TAD.

· Safety depth (height) is 4mm.

o 2mm depth the greatest inter radicular distance 2.4mm, not safe

Angulation

· A 20-30o angle, places the interradicular aspect of the miniscrw apically, where the interradicular is the greatest. This reduces root contact, increases retention with more cortical plate engagement, allows use of longer miniscrews as well as greater distalisation prior to relocation Deguchi 2006.

Extraction of 3rd molars

· Classic papers looking at the Pendulum appliance by Kinzinger 2004 showed extraction of 3rd molars resulted in greater bodily distalisation on the maxillary arch.

· However recent CBCT paper by Lee 2019 show that with miniscrew distalisation there was no difference bodily movement with extraction of 3rd molars and non-extraction.

Concept of biologic width

1-1.5mm of periodontium surrounding the implant,

Lecture title

Summary from AAO 2022 lecture: Non- compliance & Predictable class II correction with Micro implant Anchorage

Dedication

Episode is dedicated to the late Dr Anam Humdani, a London based dentist who tragically died aged 29

https://www.justgiving.com/fundraising/zayaan-humdani

· Contents: Shanya Kapoor

· Editing and Production: Farooq Ahmed

  continue reading

124集单集

所有剧集

×
 
Loading …

欢迎使用Player FM

Player FM正在网上搜索高质量的播客,以便您现在享受。它是最好的播客应用程序,适用于安卓、iPhone和网络。注册以跨设备同步订阅。

 

快速参考指南

边探索边听这个节目
播放