Measuring the Best Heat Pump System Designs

1:19:15
 
分享
 

Manage episode 351129847 series 2624149
内容由Nathan Gambling BetaTeach提供。所有播客内容(包括剧集、图形和播客描述)均由 Nathan Gambling BetaTeach 或其播客平台合作伙伴直接上传和提供。如果您认为有人在未经您许可的情况下使用您的受版权保护的作品,您可以按照此处概述的流程进行操作https://zh.player.fm/legal

Measuring Heat pump system design with Brendon from Heacol
Link to slides for the test can be found here
THE TEST RIG
Brendon discusses how he first designed the test rig with Ulster University for testing the heat pump he had built which is specifically adapted for UK climate, the UK's building stock and how the homes in the UK are commonly heated e.g. a combi boiler.
When RHI was first introduced, it required heat pumps to have costly certification and sadly Brendon's heat pump had to be put on the back burner... after all, Brendon is extremely busy installing heat pumps for people and has been putting heat pumps in for many years.
(Note, if you are an investor in innovation you'd do well to contact Brendon to discuss this heat pump)
The test rig uses a 500L thermal store to simulate the internal of a property "it's got inertia, it's got thermal capacity and it's got buffer "
A plate heat exchanger connecting the thermal store to the heat pump simulates a radiator system which can have temps and flow rates changed.
Brendon describes how this set up is able to run different testing than the excellent Energy House at Salford University and benefit from quick responses to different heating stratagies and scenarios.
TESTING SYSTEM DESIGN

  1. testing a heat pump system with 3rd party controls and buffer tank
  2. testing a heat pump system with weather compensation and buffer tank
  3. testing a heat pump system with weather compensation and no buffer tank e.g. open zone or what has been called direct in the test which can be found here

The test simulated a house with an 11.5kW heat load.
With the first test the heat pump had to run at 50 degree Celsius flow to maintain an internal temp of 21 degrees.
In the second test the flow temp dropped to 45d.
The final test, with open zone system, no buffer and controlled with manufactures wether compensation controls only required a flow temp coming from the heat pump of 35 degrees C

Support the Show.

  continue reading

章节

1. Introducing Brendon from Heacol (00:00:00)

2. Research at Ulster University on Heat Pump System (00:01:00)

3. Looking at Heat Pump System Design (00:03:31)

4. How the Test Rig Differs from the Salford University Energy House in Manchester (00:05:35)

5. Testing System Design with the Test Rig (00:09:59)

6. Compressors (00:12:27)

7. European Manufacturer's Instructions vs UK MI's vs (00:17:58)

8. Do You Need a Buffer Tank (00:19:44)

9. Explaining Different Buffer Types (00:26:11)

10. Why You Need Volume in a Heat Pump System (00:29:34)

11. Boiler Controls - On/Off Thermostats Should Have Been Banned (00:32:52)

12. Limited Knowledge in People Influencing Direction (00:37:37)

13. Explaining Open Zone Heating Systems (00:39:19)

14. Older Buildings Designed with Thermal Mass (00:43:21)

15. Brendon's Heat Pump Controller Design - plus time of use tariffs (00:45:48)

16. Designing a Heat Pumps System vs Commissioning (which is an art) (00:50:41)

17. Brendon's Self-Commissioning Controller (00:54:55)

18. The Huge Difference Between a Bad Boiler System and a Bad Heat Pump System (00:57:20)

19. Open Zone - History of the TRV (00:59:06)

20. Manufacturers Chose System Separation (e.g. Buffer) to Prevent Low Flow Errors and Not Have to Bother Training Engineers (01:02:13)

21. Local Authority's Challenge Procuring Competent Suppliers (01:03:47)

22. Ground Source Heat Pumps (01:04:53)

23. Testing Your Ground Source Heat Pump in Winter (01:08:13)

24. Licensing for Open Loop and Policy (01:09:40)

25. Such a Waste Coal Mine Water is Not Used More (01:11:35)

26. The Test Results from Different Heat Pump Systems (01:13:58)

126集单集

Artwork
icon分享
 
Manage episode 351129847 series 2624149
内容由Nathan Gambling BetaTeach提供。所有播客内容(包括剧集、图形和播客描述)均由 Nathan Gambling BetaTeach 或其播客平台合作伙伴直接上传和提供。如果您认为有人在未经您许可的情况下使用您的受版权保护的作品,您可以按照此处概述的流程进行操作https://zh.player.fm/legal

Measuring Heat pump system design with Brendon from Heacol
Link to slides for the test can be found here
THE TEST RIG
Brendon discusses how he first designed the test rig with Ulster University for testing the heat pump he had built which is specifically adapted for UK climate, the UK's building stock and how the homes in the UK are commonly heated e.g. a combi boiler.
When RHI was first introduced, it required heat pumps to have costly certification and sadly Brendon's heat pump had to be put on the back burner... after all, Brendon is extremely busy installing heat pumps for people and has been putting heat pumps in for many years.
(Note, if you are an investor in innovation you'd do well to contact Brendon to discuss this heat pump)
The test rig uses a 500L thermal store to simulate the internal of a property "it's got inertia, it's got thermal capacity and it's got buffer "
A plate heat exchanger connecting the thermal store to the heat pump simulates a radiator system which can have temps and flow rates changed.
Brendon describes how this set up is able to run different testing than the excellent Energy House at Salford University and benefit from quick responses to different heating stratagies and scenarios.
TESTING SYSTEM DESIGN

  1. testing a heat pump system with 3rd party controls and buffer tank
  2. testing a heat pump system with weather compensation and buffer tank
  3. testing a heat pump system with weather compensation and no buffer tank e.g. open zone or what has been called direct in the test which can be found here

The test simulated a house with an 11.5kW heat load.
With the first test the heat pump had to run at 50 degree Celsius flow to maintain an internal temp of 21 degrees.
In the second test the flow temp dropped to 45d.
The final test, with open zone system, no buffer and controlled with manufactures wether compensation controls only required a flow temp coming from the heat pump of 35 degrees C

Support the Show.

  continue reading

章节

1. Introducing Brendon from Heacol (00:00:00)

2. Research at Ulster University on Heat Pump System (00:01:00)

3. Looking at Heat Pump System Design (00:03:31)

4. How the Test Rig Differs from the Salford University Energy House in Manchester (00:05:35)

5. Testing System Design with the Test Rig (00:09:59)

6. Compressors (00:12:27)

7. European Manufacturer's Instructions vs UK MI's vs (00:17:58)

8. Do You Need a Buffer Tank (00:19:44)

9. Explaining Different Buffer Types (00:26:11)

10. Why You Need Volume in a Heat Pump System (00:29:34)

11. Boiler Controls - On/Off Thermostats Should Have Been Banned (00:32:52)

12. Limited Knowledge in People Influencing Direction (00:37:37)

13. Explaining Open Zone Heating Systems (00:39:19)

14. Older Buildings Designed with Thermal Mass (00:43:21)

15. Brendon's Heat Pump Controller Design - plus time of use tariffs (00:45:48)

16. Designing a Heat Pumps System vs Commissioning (which is an art) (00:50:41)

17. Brendon's Self-Commissioning Controller (00:54:55)

18. The Huge Difference Between a Bad Boiler System and a Bad Heat Pump System (00:57:20)

19. Open Zone - History of the TRV (00:59:06)

20. Manufacturers Chose System Separation (e.g. Buffer) to Prevent Low Flow Errors and Not Have to Bother Training Engineers (01:02:13)

21. Local Authority's Challenge Procuring Competent Suppliers (01:03:47)

22. Ground Source Heat Pumps (01:04:53)

23. Testing Your Ground Source Heat Pump in Winter (01:08:13)

24. Licensing for Open Loop and Policy (01:09:40)

25. Such a Waste Coal Mine Water is Not Used More (01:11:35)

26. The Test Results from Different Heat Pump Systems (01:13:58)